Mitarbeiter von Q-Tech Roding arbeiten vor dem Computertomographen ZEISS METROTOM 1500

Technologies

CT
KMS
3D Scan
“Our measurement experts enhance product quality and relieve your quality assurance department.”

To the point

Especially during the injection molding of plastic parts, metal die casting, and the processing of other moldable materials, unwanted voids and porosities frequently occur in components.

Using state-of-the-art void and porosity analyses, our measurement experts determine the number, size, and position of cavities. Furthermore, porosity measurements and the visualization of potential weak points are carried out. This provides you with valuable information about the quality of your castings.

We visualize the highly precise measurement results using clear 2D cross-sections or 3D point clouds. The evaluation and assessment of the measurement data are based on the standard norms P202 or P203. Upon request, we also take your individual standard specifications into account.

Ergebnis einer Lunkeranalyse

Our expertise at a glance

Services

  • Extensive imaging of internal air and cavities with the finest level of detail
  • Non-destructive analysis of your products 
  • Color-coded visualization of all pores and voids 
  • High-resolution 3D or 2D visualization
  • Measurement of components up to a maximum measuring volume of Ø 615 x 870 mm
  • Logging of measurement values and statistical evaluation 

Advantages

  • Void formation can also be inspected at critical points 
  • Customer-specific analyses possible with a free viewer
  • Avoidance of costly metallographic sections
  • Non-contact analysis of transparent, flexible, and soft components
  • Non-destructive detection of product and material defects
  • Spatial analysis and visualization of voids throughout the entire volume
  • Part-specific evaluation possible (hotspot analysis of voids, and much more)
  • Preventive void analysis before component processing

Our Computed Tomography Systems

ZEISS METROTOM 800 im Messlabor von Q-Tech

ZEISS METROTOM 800

  • X-ray tube: 130 kV
  • Measurement accuracy: MPE SD(TS): 2.9+L/100 µm
  • Resolution: 1536 x 1920 pixels (2K detector)
  • max. scan volume: [mm] Ø 275 x 360
  • Accreditation: yes
ZEISS METROTOM 1500 im Messlabor von Q-Tech

ZEISS METROTOM 1500

  • X-ray tube: 225 kV
  • Measurement accuracy: MPE SD(TS): 4.5+L/50 µm
  • Resolution: 3072 x 3072 pixels (3K detector)
  • max. scan volume: [mm] Ø 615 x 870