Mitarbeiter von Q-Tech Roding arbeiten vor dem Computertomographen ZEISS METROTOM 1500

Technologies

CT
KMS
3D-Scan
"For optimal process reliability and the highest level of quality control, both internally and externally."

Precisely

Beispiel eines Ist-Ist-Vergleichs

With the help of actual-actual comparison, component deviations can be precisely determined, for example, for re-qualification purposes. This method thus represents a cost-effective and resource-saving alternative to conventional testing procedures.

Using computed tomography or 3D scanning, meaningful data is digitized and acquired in just a few minutes. The subsequent evaluation of product quality and a clear false-color representation enable the precise identification and calculation of deviations. Discrepancies are clearly visible to employees.

Through this comparison, statements about the relationship between two components can be made more quickly, and optimizations can be implemented early, even without prior measurement and programming.

Our expertise at a glance

Services

  • Non-destructive Measuring & Analyzing
  • Geometry comparison with color-coded 3D and 2D visualization of all deviations
  • High-resolution representation of the finest geometries
  • Measurement of components up to a maximum measurement volume of Ø 615 x 870 mm
  • Comprehensive imaging of all internal areas with exquisite detail 

Advantages

  • Time savings compared to tactile testing and measurement methods
  • Most economical measurement method for re-qualification of components and assemblies
  • Various orientations possible depending on the application
  • Customer-specific analyses possible with a free viewer
  • Non-contact comparison of transparent, flexible, and soft components
  • High-precision geometry representation with several million measurement points
  • Mapping of general profile specifications
  • Non-destructive identification of product defects
  • Avoidance of costly component sectioning

Our CT Scanners

ZEISS METROTOM 800 im Messlabor von Q-Tech

ZEISS METROTOM 800

  • X-ray tube: 130 kV
  • Measurement accuracy: MPE SD(TS): 2.9+L/100 µm
  • Resolution: 1536 x 1920 pixels (2K detector)
  • max. measurement volume: [mm] Ø 275 x 360
  • Accreditation: yes
ZEISS METROTOM 1500 im Messlabor von Q-Tech

ZEISS METROTOM 1500

  • X-ray tube: 225 kV
  • Measurement accuracy: MPE SD(TS): 4.5+L/50 µm
  • Resolution: 3072 x 3072 pixels (3K detector)
  • max. measurement volume: [mm] Ø 615 x 870